Air-Cooled Aftercoolers

The air-cooled aftercooler's compact design is ideal for packaged compressors and sites with limited space. Heavy-duty steel housing and durable leg construction mean reliability under even the most adverse industrial conditions. The cooling process occurs as compressed air enters the aftercooler as a superheated vapor between 200 and 400 degrees F. Maximum cooling is assured by the staggered tubing design with external aluminum fins, while further design advantages include minimal energy consumption.

Product Features

  • Compact
  • Heavy Duty Industrial Grade Construction
  • Rigid and Durable Air in/out Connections
  • Eliminates need for Flex Connections
  • TEFC Motors Available
  • Low Energy Cost
  • Meets all OSHA Requirements
  • Copper and aluminum fin available
  • Aluminum core
  • PED, CRN coded

Additional Options

  • Air Motors With Mufflers
  • Special Coatings (i.e. Corrosion Resistant)
  • Alternate Materials available for
    • Tube
    • Fin
    • Housing
  • Custom Designs Available
Air Cooled Aftercooler Model Maximum Capacity
(SCFM Approach) *
Dimensions (Inches) Air In/Out Connections Weight (lbs.) Fan Horsepower Typical Compressor Horsepower Recommended IPAC Separator**
5 10 15 20 A B C
Small Range A010 thru A050
A01000B00 24 36 50 64 34.20 11.50 18.50 1-1/2″ NPT 42 1/25 10 to 15 WS01
A03000B00 58 88 125 140 38.20 14.00 20.30 1-1/2″ NPT 60 1/25 30 WS02
A05000B00 90 150 210 230 42.40 16.40 23.40 1-1/2″ NPT 90 1/6 40 WS03
Mid Range A010 thru A050
A08030T00 150 230 300 370 57.00 22.90 41.00 2″ NPT 215 1/4 50 to 70 WS03
A1603T000 277 402 670 720 62.20 27.30 50.00 2-1/2″ NPT 345 3/4 125 S04H
Large Range A010 thru A050
A2003T000 316 528 790 830 78.20 37.00 56.00 2-1/2″ FLG 550 3/4 150 S04H
A2403T000 350 780 1,010 1,100 78.20 38.00 56.00 3″ FLG 600 1-1/2 200 S04AH
A3203T000 550 830 1,250 1,400 78.20 38.00 56.00 3″ FLG 700 1-1/2 250 S04AH
A4003T000 578 940 1,500 1,600 78.20 38.00 56.00 4″ FLG 750 1-1/2 300 S05H
A4803T000 1,183 1,666 2,010 2,485 78.20 38.00 99.90 5″ FLG 1,400 2 @ 1-1/2 350 S06H
A6403T000 1,340 1,800 2,470 3,010 78.20 38.00 101.70 5″ FLG 1,500 2 @ 1-1/2 400 S06H
A7503T000 1,475 2,090 2,800 3,500 78.20 38.00 101.70 5″ FLG 1,600 2 @ 1-1/2 700 S06H

Notes

  • *Maximum SCFM Capacity is based upon 250°F inlet compressed air @ 100 PSIG
  • Ambient conditions are 75°F, 50% RH.
  • **Recommended IPAC drain trap for all models – SAC120
  • IPAC's Air Cooled Aftercoolers are designed with maximum working pressure of 200 PSIG at 400°F.
  • Model A0100B00 and A03000B00 are 115/1/60 (ODP).
  • Model A0500TB00 is available 115/1/60 (TEAO) or 230/1/60 (ODP).
  • Model A0803T000 through A7503T00 are 230/460/3/60 (TEFC).
  • Other power variations available upon request – consult factory.
  • Air motor option available on all sizes – consult factory.
  • Maximum working pressure for Models WS01 – WS03 230 PSIG; all other models 200 PSIG.